Cation suppression in ion chromatography

Cation suppression in ion chromatography

Chemistry & Biochemistry / Water & Beverages

March 21, 2016

Trace analysis of cations, amines, and transition metals is possible with or without suppression. However, some applications require particularly high sensitivity of the analysis. This can only be achieved by sequential suppression, as suppression considerably lowers the detection limits for the analytes. Such analyses are common, for instance, in power plant applications or in pharmaceutical applications. Moreover, there are a number of norms and standards that request cation analysis with suppression. In short, suppression reduces background conductivity to a minimum and decreases baseline noise. Both effects together improve the signal-to-noise ratio and increase the sensitivity of the measuring system. Thus, whenever the quantification of very low concentrations of cations is required, analysis with sequential suppression is the method of choice.

The Metrohm Suppressor Module

The patented Metrohm Suppressor Module (MSM) is a very effective and highly robust solution when suppression is needed. The heart of the MSM is a small rotor that contains three cartridges, filled with anion exchange resin. While the first cartridge is being used for suppression, the second one is regenerated. At the same time, the third cartridge is rinsed to remove any residual regenerant. As the cartridges are rotated one step before each new injection, there is always a freshly regenerated suppressor cartridge ready for the next injection.

STREAM – the green way of suppression

STREAM (Suppressor Treatment Re-using Eluent After Measurement) adds even more benefits to the suppression technique described. STREAM refers to a process whereby, instead of simply disposing of the suppressed eluent after detection, it is used to rinse the regenerated suppressor unit. Moreover, the use of the STREAM technique results in considerably lower consumption of regenerant.

STREAM enables users to perform sustainable, «green chemistry» while saving on operating costs. Moreover, longer system run times frees up more time for the user to perform other tasks in the laboratory.

IDEXX Colilert-18/Quanti-Tray Test Becomes the New ISO Standard 9308-2:2012

IDEXX Colilert-18/Quanti-Tray Test Becomes the New ISO Standard 9308-2:2012

Chemistry & Biochemistry / Water & Beverages

IDEXX announces that its Colilert®-18/Quanti-Tray® test becomes the new International Organization for Standardization (ISO) worldwide standard for detecting total coliforms and E. coli in water. The Organization has withdrawn ISO 9308-2:1990, which follows the multiple tube (most probable number) method, and replaced it with ISO 9308-2:2012 using the Colilert-18/Quanti-Tray method.

August 01, 2013 More +
Cubis®High-Capacity Micro Balances: Weigh Minimum Amounts of Sample Directly into Heavy Flasks

Cubis®High-Capacity Micro Balances: Weigh Minimum Amounts of Sample Directly into Heavy Flasks

Chemistry & Biochemistry / Water & Beverages

With a unique resolution of up to 60 million divisions and a readability of 1 μg, the new high-capacity Cubis® MSA66S micro-analytical balances feature a maximum capacity of 61 g.
Based on this high weighing capacity, you will no longer need to transfer samples and can weigh minimum amounts directly into relatively heavy containers, such as long-necked flasks or HPLC bottles, saving an extra step in your procedure, ensuring that you can use 100% of your sample.

 

 

January 17, 2018 More +